Expert calibration lab in
Chicago, Illinois

Opening hours

Mon
07:00 - 03:30
Tue
07:00 - 03:30
Wed
07:00 - 03:30
Thu
07:00 - 03:30
Fri
07:00 - 03:30
Contato
(847) 718-0172
718 West Algonquin Road
Arlington Heights, IL 60005

ACREDITAÇÕES

  • A2LA certificate #1022.03
  • ISO 17025
  • ANSI/NCSL Z540-1
  • ANSI/NCSL Z540.3
Scope of accreditation
A2LA Cert #1022.03

A2LA Cert #1022.03

ISO/IEC 17025

ISO/IEC 17025

ANSI/NCSL Z540-1

ANSI/NCSL Z540-1

ANSI/NCSL Z540.3

ANSI/NCSL Z540.3

CAPACIDADES

Accredited Capabilities
Traceable Capabilities
Química
Dimensional
Electricity
Força
Dureza
Umidade
Mass / Scale
Pressure / Vacuum
Temperatura
Time / Frequency
Torque
Química

Química

Non-accredited Capabilities

Common equipment serviced: PH meters, Conductivity meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Dimensional

Accredited Capabilities

Global Calibration Scope

  • External diameter: 0.003-0.5″
  • Rulers & Tapes: up to 100ft

Common equipment serviced: Plug gauges, Steel rules, Tape measures, Length standards

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricity

Electricity

Accredited Capabilities

Global Calibration Scope

  • DC voltage gererate: up to 1100V
  • Voltage measure: 70kVDC/50kVAC
  • DC current generate: up to 1025A (coil)

Common equipment serviced: Power supplies, Multimeters, Hypot, Insulation testers, Oscilloscopes, Clamp meter, Daq cards, Resistance meters, Digital thermometer-simulate

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Força

Força

Accredited Capabilities

Global Calibration Scope

  • Force up to 25kLbs

Common equipment serviced: Load cells, Force gauges, Dynamometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dureza

Dureza

Non-accredited Capabilities

Common equipment serviced: Rockwell hardness testers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Umidade

Umidade

Accredited Capabilities

Global Calibration Scope

  • 1022.03

Common equipment serviced: Temperature humdity meters, Humidity sensors

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Mass / Scale

Mass / Scale

Accredited Capabilities

Global Calibration Scope

  • Up to 2400lbs using the substitution method

Common equipment serviced: Scales, Balances, Hanging scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Accredited Capabilities

Global Calibration Scope

  • Pressure pneumatic: -15 to 1500 PSI
  • Pressure hydraulic: 10 to 10000 PSI

Common equipment serviced: Pressure gauges, Vacuum gauges, Pressure transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperatura

Temperatura

Accredited Capabilities

Global Calibration Scope

  • Tempature measure: -197 to 600°C
  • Temp generate: -78 to 600°C
  • Blockbody: -15 to 500°Ci

Common equipment serviced: Thermometers, Ovens, Enviromental chambers, Temperature probes / tc, Baths, Furnaces, Temperature probes, Infrared thermometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Time / Frequency

Accredited Capabilities

Global Calibration Scope

  • Rabidium oscillator
  • Timometer
  • Up to 100000 RPMs

Common equipment serviced: Frequency counters, Tachometers-optical, Stop watches

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Torque

Torque

Accredited Capabilities

Global Calibration Scope

  • 4in-oz to 600ft-lbs

Common equipment serviced: Torque wrenches, Torque drivers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Química

Common equipment serviced: PH meters, Conductivity meters

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Global Calibration Scope

  • External diameter: 0.003-0.5″
  • Rulers & Tapes: up to 100ft

Common equipment serviced: Plug gauges, Steel rules, Tape measures, Length standards

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Electricity

Global Calibration Scope

  • DC voltage gererate: up to 1100V
  • Voltage measure: 70kVDC/50kVAC
  • DC current generate: up to 1025A (coil)

Common equipment serviced: Power supplies, Multimeters, Hypot, Insulation testers, Oscilloscopes, Clamp meter, Daq cards, Resistance meters, Digital thermometer-simulate

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Força

Global Calibration Scope

  • Force up to 25kLbs

Common equipment serviced: Load cells, Force gauges, Dynamometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dureza

Common equipment serviced: Rockwell hardness testers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Umidade

Global Calibration Scope

  • 1022.03

Common equipment serviced: Temperature humdity meters, Humidity sensors

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Massa / Balanças

Global Calibration Scope

  • Up to 2400lbs using the substitution method

Common equipment serviced: Scales, Balances, Hanging scales

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressão / Vácuo

Global Calibration Scope

  • Pressure pneumatic: -15 to 1500 PSI
  • Pressure hydraulic: 10 to 10000 PSI

Common equipment serviced: Pressure gauges, Vacuum gauges, Pressure transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Temperatura

Global Calibration Scope

  • Tempature measure: -197 to 600°C
  • Temp generate: -78 to 600°C
  • Blockbody: -15 to 500°Ci

Common equipment serviced: Thermometers, Ovens, Enviromental chambers, Temperature probes / tc, Baths, Furnaces, Temperature probes, Infrared thermometers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Tempo / Frequência

Global Calibration Scope

  • Rabidium oscillator
  • Timometer
  • Up to 100000 RPMs

Common equipment serviced: Frequency counters, Tachometers-optical, Stop watches

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Torque

Global Calibration Scope

  • 4in-oz to 600ft-lbs

Common equipment serviced: Torque wrenches, Torque drivers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Secret Link